Skip to main content

FLY-LLL Flux Buffer Automatic Filament Refill System

Loading...

The FLY-LLL Flux Buffer is a dual-channel automatic filament refill system. Each motor channel includes two sensors for filament in and out, and the buffer contains 4 position sensors used to control feeding, stopping, retracting, and channel switching.

Product Information

ItemSpecification
Current Firmware VersionV2.0.7
Control BoardSTM32F072C
Number of Local Channels2
Motor DriverTwo Stepper Motor Drivers
Input VoltageDC 12-24V

Configuration Tools: FLY-LLL Flux Buffer Configuration Tool

Can read the device's currently saved parameters and automatically refresh the status of up to 8 sensors; slave controllers not connected to a local buffer display 4 motor sensors.

Main Features

  • Automatic loading, stopping, and retracting for two filament channels.
  • Controls the feeding action of the current channel via buffer position.
  • When the current filament runs out, searches for the next available channel in automatic refill mode.
  • Buttons control individual channel forward, reverse, and mode switching.
  • Sensor calibration values, speed, current, and operating mode can be saved to the device.
  • Motor timeout, over-distance, sensor abnormality, and watchdog protection.

Sensor Description

PositionNameFunction
Motor Channel 0S1Detects filament entering the channel
Motor Channel 0S2Detects filament reaching the motor outlet
Motor Channel 1S1Detects filament entering the channel
Motor Channel 1S2Detects filament reaching the motor outlet
BufferB1Detects filament presence in the buffer filament path
BufferB2Forward position, triggers feeding
BufferB3Stop position, triggers stopping feed
BufferB4Retraction position, triggers retraction
Loading...

Pre-Use Checks

Power Off Operation

Before inspecting wiring, connectors, or mechanical structures, completely turn off the printer and disconnect the power supply. Do not plug or unplug wiring, rearrange interface wires, or touch terminals while powered on.

  1. Confirm the filament path is clear and the feed wheel pressure is appropriate.
  2. Confirm all motor, buffer, button, and indicator light wiring connections are secure.
  3. Confirm no fingers, tools, or loose wires are near any moving parts.
  4. After the first use or after replacing the main controller firmware, perform sensor calibration and testing first.

Sensor Calibration and Testing: Open Sensor Calibration and Testing