EDDY Sensor FAQ Troubleshooting Guide
EDDY Sensor Troubleshooting Guide
Issue 1: Error Error during homing z: Eddy current sensor error during homing
If you encounter this error, please try the following methods in order:
Method 1: Update Klipper
Important Notice
There were previously compatibility issues with EDDY's Z homing function, which have been optimized in the Klipper update from January 6, 2026. Please perform the following operations based on your host type:
- If using a standard host, please update Klipper to the latest version.
- If using a FLY host, please upgrade the system version to V1.3.5 or higher. Please note: After completing the above updates, you need to recalibrate the EDDY sensor.
Method 2: Adjust Drive Current
- Open the
printer.cfgfile. - Find the
reg_drive_current =parameter at the bottom of the configuration. - Increase or decrease its current value by 1 (e.g., if it's
15, change it to16or14). - Note: Please enter the calculated result directly (e.g.,
16), do not enter an expression (e.g.,15+1). - Save the file and restart the printer, then test homing again.
Loading...
Method 3: Adjust Probe Offset If Method A is ineffective:
- In
printer.cfg, find the[probe_eddy_current fly_eddy_probe]configuration section. - Increase the
z_offset:value within it (default is1.0, try2.0or2.5first). - Important Notes:
- This parameter must only be configured here once; do not configure it elsewhere.
- It is recommended not to exceed
3.0. The specific value depends on your machine's hardware.
- Save and restart the printer, then test.
Loading...
Issue 2: Prompt !! probe_eddy_current sensor not in valid range
This error indicates the probe reading is outside the valid range.
- Main Cause: After enabling the EDDY probe, the probing heights set elsewhere (e.g., in the
[Horizontal_move_Z]or[bed_mesh]modules) might not take effect, causing the probe to move beyond its physical range. - Solution: Please check and ensure that all configured probing heights involving the probe's descent are within the sensor's valid range.
Loading...
Important Reminders
- Empirical Reference for
z_offsetValue: Based on numerous cases we've handled, setting the initialz_offsetvalue in[probe_eddy_current fly_eddy_probe]to2.5often allows many EDDY sensors to become operational relatively quickly. You can use this as an efficient debugging starting point. - Important Clarification: This is not a universal fixed value nor an official default configuration. The optimal probe offset strictly depends on your machine's specific hardware (e.g., probe mounting position).
Loading...